Conventional 8-Zone Fire Alarm Panel

Conventional 8-Zone Fire Alarm Panel

KES 19,000
Category: Fire Alarm Systems · In stock · Sold and installed by Qyvea Limited

A conventional fire alarm control panel with 8 zones, relay outputs and battery backup -- the central unit that receives signals from smoke and heat detectors and triggers sounders, suited to small and medium commercial buildings.

What the 8-Zone Fire Alarm Panel is

This is a conventional (as opposed to addressable) fire alarm control panel with 8 zones -- meaning up to 8 separate detection circuits can be wired in, each covering an area of the building, with the panel showing which zone triggered rather than which exact detector. It includes relay outputs for triggering sounders or other equipment, and battery backup so the system keeps working through a power outage.

Who the 8-Zone Fire Alarm Panel is built for

Small offices

A straightforward, cost-effective panel for a building with a handful of zones.

Shops & retail units

Basic zone-level fire detection for a commercial premises.

Schools & small institutions

Covers multiple rooms or blocks as separate zones.

Warehouses

Zone coverage across different storage or work areas.

Upgrading from no fire alarm

An accessible entry point into proper fire detection.

Contractors & installers

A standard conventional panel to specify into smaller projects.

8-Zone Fire Alarm Panel specifications

  • Zones -- 8 independent detection zones
  • Panel type -- conventional -- zone-level rather than individual-device addressing
  • Outputs -- relay outputs for sounders and other triggered equipment
  • Backup power -- battery backup keeps the panel operating through outages
  • Best suited to -- small and medium commercial buildings

Specifications, Compatibility & Requirements

Specifications

Zones8
Panel typeConventional
OutputsRelay
BackupBattery

Compatibility

  • Works with standard conventional smoke, heat and multi-sensor detectors
  • Compatible with standard sounders and strobes wired per zone

Installation Requirements

  • A wired zone layout across the building
  • A mounting location for the panel with access for testing and maintenance
  • A power supply near the panel

Power Requirements

Mains AC with battery backup for outage protection.

Storage Requirements

Not applicable for this product.

Networking Requirements

Not applicable for this product. this is a conventional, not network-connected, panel.

Warranty

Warranty terms are set by the supplying distributor and confirmed at the time of purchase -- ask us for the current terms before ordering.

Downloads

Official datasheet available on request -- ask us on WhatsApp.

Product, installation, maintenance and support

The 8-Zone Fire Alarm Panel is one part of a bigger picture -- here's how it connects to the rest of what Qyvea offers.

Installing the 8-Zone Fire Alarm Panel

A fire alarm panel is only as good as the detectors, wiring and zone planning behind it -- installation should be done to match the building's layout and relevant standards. Qyvea installs this panel as part of a full Fire Alarm Installation, including detector placement, wiring and commissioning.

Maintenance & support

Fire alarm systems need regular testing and servicing to stay reliable and, in many cases, compliant. Qyvea offers ongoing fire alarm maintenance, whether the panel was installed by us or someone else.

8-Zone Fire Alarm Panel questions

What's the difference between conventional and addressable fire alarm panels?

A conventional panel like this one identifies which zone (area) triggered an alarm, while an addressable panel identifies the exact device. Conventional panels are more cost-effective and suit smaller buildings with fewer zones.

How many detectors can be connected to one zone?

This depends on the detector type and wiring, but each of the 8 zones can typically support multiple detectors covering a defined area, following standard fire alarm design practice.

Does the panel keep working during a power cut?

Yes -- it includes battery backup so the system continues operating through outages, which is a standard requirement for fire alarm systems.

Does Qyvea install this panel, or only sell it?

Both. Buy it alone for your own installer, or have Qyvea supply and install it as part of a full fire alarm project including detectors and commissioning.

What does fire alarm installation cost in Kenya?

Cost depends on the number of zones actually used, detector count and building layout. Qyvea provides a free site survey and itemised quote alongside the panel price.

Buy the fire alarm panel -- or have it installed

KES 19,000 unit price. Free site survey if you'd like Qyvea to supply and install the full system.

Related Qyvea pages

Chat with us — 30 min response